SUBMERSIBLE PUMP CABLE Specifications

SUBMERSIBLE PUMP CABLE

APPLICATION

The nitrile PVC sheath has excellent water, oil as well as abrasion resistant properties allowing for use in borehole and submersible pumps, sewerage extraction plants as well as engine rooms.

MOST OFTEN USED BY

Electricians, electrical contractors, farmers, D.I.Y enthusiasts.

SPECIFICATION SABS 1574

x
Voltage Rating
600/1000 volts
Spark Test Voltage
6000 volts (rms)
Voltage Withstand Test
2.5 kV for 10 mins after 2 hours in the water
Conductor
Annealed PCW class 5.
Temperature Range
-10 to + 70 °C
Insulation
General purpose PVC
Sheathing
Nitrile PVC

PACKAGING

100 m shrink-wrapped coils or on 500 to 1000 m length Wooden drums

TECHNICAL DATA

Size - (mm²) - mm² Individual wire OD - Nom. mm Nom. Core diameter - mm Current rating - Ampere Volt Drop - mV/A/m Mass - kg/100m
1.5
0.242
9.9
16
30.0
13.7
2.5
0.242
11.9
25
20.0
20.2
4
0.300
13.2
32
12.0
27.6
6
0.300
14.7
37
8.0
36.4
10
0.300
16.8
50
5.0
53.0
16
0.300
19.4
65
3.0
73.0

Maximum conductor temperature 70°C ; ambient air temperature 30°C
Current Ratings as per SANS 10142-1:2005 Table 6.2(a) Installation Method 2

Size - (mm²) - mm² Individual wire OD - Nom. mm Nom. Core diameter - mm Current rating - Ampere Volt Drop - mV/A/m Mass - kg/100m
1.5
0.242
10.7
16
30.0
16.7
2.5
0.242
13.1
25
20.0
25.5
4
0.300
14.3
32
12.0
34.3
6
0.300
16.0
37
8.0
45.6
10
0.300
18.3
50
5.0
67.0
16
0.300
21.4
65
3.0
92.9